Shopping security
The Allen-Bradley 1404-M405A-DNT serves as the primary processing core and intelligence unit for the Powermonitor 3000 sub-metering system. This panel-mounted master module delivers comprehensive, revenue-grade diagnostics across three-phase electrical networks by measuring true RMS voltage, current, real/reactive/apparent power parameters, and total consumption metrics. Featuring integrated DeviceNet and RS-485 communication protocols, the module streams real-time power quality analytics directly to programmable logic controllers (PLCs) and facility-wide SCADA monitoring stations. We provide this electrical component as a 100% brand new, original factory unit to ensure precise diagnostic accuracy and immediate plant integration.
The following comprehensive table outlines the electrical boundaries, input tolerances, and functional capacities of the 1404-M405A-DNT master module:
| Specification | Details |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Catalog Number | 1404-M405A-DNT |
| Product Series | Powermonitor 3000 |
| Condition | 100% Brand New Original Factory Packaging |
| Product Type | Master Power Monitoring Module |
| Supported Network Connectivity | DeviceNet and RS-485 Networks |
| Control Power Input Range | 120-240 V AC (50/60 Hz) or 125-250 V DC |
| Maximum Control Power Dissipation | 15 VA Maximum |
| Nominal Voltage Inputs | 480 V AC Line-to-Line |
| Voltage Input Detection Range | 20-600 V AC Line-to-Line |
| Burden on Voltage Inputs | Less than 0.5 VA Per Single Phase Input |
| Nominal Current Transformer Input | 5 A AC Secondary Output (External CT Required) |
| Burden on Current Inputs | Less than 0.5 VA Per Single Phase Input |
| Integrated Digital Inputs | 4 Optically Isolated Inputs (18-30 V DC, 6 mA at 24 V DC) |
| Integrated Relay Outputs | 4 Form C Relays (Rated at 240 V AC, 2 A Resistive Load) |
| Operating Ambient Temperature | 0 to 55 degrees C (32 to 131 degrees F) |
| Physical Module Dimensions | 190 x 115 x 145 mm (7.48 x 4.53 x 5.71 inches) |
| Net Module Weight | 1.42 kg (3.13 lbs) |
Revenue-Grade Power Diagnostics: The module processes raw analog phase waves through internal high-speed DSP circuits to deliver 1% revenue-grade metering precision. This level of precision eliminates estimation errors, allowing facility managers to utilize data safely for utility sub-metering and internal cost-center billing.
Autonomous Automated Load Control: Four integrated Form C mechanical relays allow the module to execute local load-shedding commands without waiting for a PLC intervention loop. When demand spikes past pre-set thresholds, the internal contacts drop out instantly to disconnect non-essential downstream motors or heating banks.
Optical Transient Protection for Digital Inputs: The four onboard digital inputs feature 24V DC optical isolation circuits. This barrier blocks industrial high-voltage switching surges and inductive line noise, preventing field-side voltage spikes from bleeding backward into the sensitive core monitoring microprocessors.
Dual AC/DC Universal Control Power: The flexible power stage accepts a broad input array spanning 120-240V AC or 125-250V DC. This adaptability ensures uninterrupted instrumentation logging even when severe line brownouts degrade standard facility AC supply networks.
Direct Integration into Automation Tags: The native DeviceNet network interface permits automatic hardware mapping into Logix memory structures. Engineers pull voltage imbalances, total harmonic distortion values, and power factor logs into PLC rungs without writing convoluted ASCII data parsers.
Can I wire the 1404-M405A-DNT current sensing lines directly to the main high-voltage busbars?
No. You must never connect high-voltage power lines directly to the current inputs of this module. The 1404-M405A-DNT requires standard external current transformers (CTs) with a nominal 5 A AC secondary output to reduce line currents to safe operational sensing thresholds.
How does the unit retain stored energy logs and historical peak demand data during an absolute power outage?
The master module utilizes internal non-volatile data logging sectors. It saves critical billing data, event history records, and hardware calibration tables permanently without relying on external lithium batteries or continuous control power feeds.
What is the significance of the low burden rating on the voltage and current transformer inputs?
The module exhibits a tiny burden rating of less than 0.5 VA per input phase. This low burden ensures that the monitoring unit draws virtually zero power from the measurement loop, preventing the meter itself from skewing or distorting downstream loop voltage and current signals.
Ships within 48 hours · Estimated delivery Jun 25 - Jun 30
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order